Pay attention to the log lines that appear right before the rig goes offline. Apart from this, you can launch this command via Hive Shell:
tail -f /var/log/syslog
(you can interrupt the command by pressing the keys Ctrl-C).
When the rig goes offline, Hive Shell will disconnect, and you will see the required lines on the screen.
To reduce the consumption of your GPUs (when using Hiveon OS), you can specify the parameters of the core voltage and memory individually for each card.
To do this, go to the Overclocking section on your worker and specify the necessary values in the overclocking profile. Please note that in the Memory Status column you can indicate both the status index 0, 1, or 2, and the voltage in mW.
Also, to reduce power consumption, you can use the aggressive undervolting mode:
In order to check the availability of the Internet on your rig, you need a screen and a keyboard for a physical connection to the rig. After the Hiveon OS loading is complete, enter the command net-test
. After you apply it, you will see the availability status of Hiveon OS servers.
In most cases, this error occurs due to the malfunctioning of the video card's riser. Please check the power connector on the riser for a burnt wire, and replace the riser.
DPM is a table of core frequencies and the corresponding voltages of these frequencies. This information can be checked with the amd-info
command. The video card changes the core frequencies in steps according to this table.
The manufacturer with a large margin sets the voltages for each stage of the core frequency. Our task is to select the lowest voltage value for the selected core frequency specified in DPM, but at the same time to ensure that the card continues to mine steadily. In this way we get reduced consumption without losing performance. This is downvolt. Here are the examples:
By default, Hiveon OS uses the value DPM 5. The factory value on Windows is DPM 7 Windows. Specifying core frequency works, but not on all the cards. But using the DPM value definitely works on all video cards.
Go to the rig's Settings:
Scroll down and click the Advanced settings button:
Select the desired farm from the drop-down list and click the Transfer button.:
To start the mc editor, launch Hive Shell on your worker. Then enter the mc
command.
Using Hive Shell, enter the working rig located in the same local network as the frozen one.
Enter this command: ssh user@”Ip_address_of_the_frozen_rig”
:
Then enter your password for this rig. The latest IP address of the rig can be checked in the Hiveon OS dashboard . Now you can check if the rig has really frozen or turned off, or if it is a glitch of the web-server.
The exit
command will every time bring you back in the chain.
Load Average is the average number of executable processes over a given time. For example, if the hourly load average is 10, this means (for a uniprocessor system) that at any given time during that hour, 1 process is running, and 9 are ready to run (not blocked for input/output) and are waiting for the processor to become "free".
If you have Celeron G3930 with two cores, then LA 2 indicates 100% system load. For Ethash, this is very abnormal, but for modern algorithms — it is okay.
The maximum value of LA can be anything. This is the length of the queue to the processor, expressed in the number of cores of this processor. LA has always been counted as the number of computing devices required to complete the entire current task queue.
When mining Beam and Cuckoo on weak processors, LA can reach up to 3-4. If you don't like the red color of the indicator, you can always set the threshold value here:
Three values: LA now / average LA per 5 minutes / average LA per 15 minutes .